Neisseria gonorrhoeae (GC) Amplified Nucleic Acid Detection
General Information
Lab Name
N gon(GC) Nucleic Acid Detectn
Lab Code
GCCAD
Epic Name
Gonorrhea Nucleic Acid Detection
Description
Order GCCTAD to R/O both GC and (Chlamydia trachomatis) on same specimen.
This testing is not intended for the evaluation of suspected sexual abuse or for other medico-legal indications.
Synonyms
GC-Amplification, Gonorrhea-Amplification, NAA, Neisseria-Amplification
Components
Code | Name |
---|---|
GCADSD | N.gon(GC) NA Spec Description |
GCAD | N.gonorrhoeae(GC) Nucleic Acid |
Interpretation
Method
Nucleic Acid Amplification
Reference Range
See individual components
Guidelines
Ordering & Collection
Specimen Type
Collection
Endocervical or urethral specimen: Collect using the APTIMA Unisex Swab kit. Collect specimen with narrow-tipped APTIMA swab (labeled APTIMA Unisex Collection Swab); place swab in APTIMA Swab transport tube. (Large swab labeled APTIMA Cleaning Swab is used only to remove excess cervical mucus before collecting specimen with small swab. Discard large swab after cleaning cervix.)
Vagina: Collect vaginal specimen using the APTIMA Vaginal Swab Specimen Collection Kit. NOTE: The test performance of vaginal swab specimens has not been evaluated in pregnant women or women less than 16 years of age.
Throat: Collect throat/pharynx specimens using the APTIMA Vaginal Swab Specimen Collection Kit.
Anal: Collect anal/rectal specimens using the APTIMA Vaginal Swab Specimen Collection Kit. Avoid collecting stool on the swab.
Urine: Collect first stream of first morning void (Dirty catch for maximal sensitivity) or first stream at least 1 hour after last void in urine cup.
Also acceptable: Wait at least 1 hour after last void, then collect first stream urine in urine cup.
Unacceptable specimens: Catheterized urine, Frozen urine, unpreserved urine received >24 hours after collection, gel-based culture swab.
Handling Instructions
Swab or Urine in APTIMA tube: Transport under ambient conditions within 30 days
Unpreserved urine: Transport under ambient conditions within 24 hours; specimens received after 24 hours will be rejected.
Quantity
requested: Swab in APTIMA tube, 2 mL urine in APTIMA urine tube, or 20 mL urine in cup
minimum: Swab in APTIMA tube, 2 mL urine in APTIMA urine tube, or 20 mL urine in cup
Processing
Alert! Unpreserved urine must be transferred to an APTIMA urine tube within 24 hours of collection.
Login:
Order CHLAD if only CT (R/O Chlamydia trachomatis) is requested.
Order GCCAD if only GC (R/O Neisseria gonorrhoeae) is requested.
Order GCCTAD when R/O both GC and CT are requested.
Performance
LIS Dept Code
Serology (SR)
Performing Location(s)
HMC |
Microbiology
206-744-5858 325 9th Ave, Rm # GWH-47, Seattle, WA 98104-2420 |
---|
Frequency
Set up: 6 days a week, Monday - Saturday.
Available STAT?
No