Histoplasma Antigen Immunoassay (Sendout)

General Information

Lab Name

Histoplasma Ag Immunoassay

Lab Code

RHISTO

Epic Name

Histoplasma Antigen, Quant, Serum (Sendout)

External Test Id

310

Description

Useful For: The histoplasma quantitative antigen test aids the diagnosis of histoplasmosis. Monitoring the histoplasmosis helps determine when treatment can be stopped and to diagnose relapse.

Synonyms

FHIST, Histo Polysaccharides, Histoplasma Antigen, Histoplasma capsulatum Antigen, Histoplasma Polysaccharide Antigen

Components

Code Name
RHISAG Histoplasma Ag Immunoassay
RHSTAI Histoplasma Ag Interp

Interpretation

Method

Enzyme Immunoassay (EIA)

Reference Range

See individual components

Ref. Range Notes

Reference Interval: None Detected

Reportable Range:

  • Positive results reported in ng/mL from 0.20 ng/mL to 20.00 ng/mL.
  • Positive results above 20.00 ng/mL are reported as "Above the Limit of Quantification."

Interferences and Limitations

Cautions: Sodium hydroxide and sputolysin. Cross-reactivity occurs between blastomycosis and histoplasmosis, and in Paracoccidioidomycosis, penicillosis, coccidioidomycosis, aspergillosis, and sporotrichosis.

Guidelines

Ordering & Collection

Specimen Type

Blood

Collection

6 mL blood in RED TOP Tube or GOLD SST

Forms & Requisitions

Handling Instructions

Outside Laboratories: Centrifuge sample and transfer serum to a separate plastic vial. Refrigerate serum.

Stability: Refrigerated (preferred): 14 days; Frozen: Frozen: Indefinitely; Ambient: Unacceptable.

Reject Due To: Specimen that is too viscous to pipette. Tissue, biopsy, sputum, bronchial aspirate, FNA, bone marrow aspirate, stool or samples in transport media, fixative or Isolator tubes.

Quantity

requested: 2 mL serum
minimum: 1.2 mL serum

Processing

Centrifuge sample and transfer serum to a separate plastic vial. Refrigerate serum.

Sendouts:

  • Order Miravista Diagnostics Test: 310 (Histoplasma Quantitative EIA Test).
    • Select specimen type 'serum.'
  • Ship via FedEx priority overnight, Monday through Thursday only. Saturday delivery is not available.

Stability: Refrigerated (Preferred): 14 days; Frozen: Indefinitely; Ambient: Unacceptable.

Reject Due To: Specimen that is too viscous to pipette. Tissue, biopsy, sputum, bronchial aspirate, FNA, bone marrow aspirate, stool or samples in transport media, fixative or Isolator tubes.

Performance

LIS Dept Code

Sendouts (SO)

Performing Location(s)

Sendout MiraVista Diagnostics
800-647-2847

4705 Decatur Blvd
Indianapolis, IN 46241

Frequency

Performed: Monday - Saturday. Report Available: 1-6 days.

Available STAT?

No

Billing & Coding

CPT codes

87385

LOINC

51753-2